Numatic NVM-2BH dust bags
If your machine is one of the models below, the bag you need is the Numatic NVM-2BH.
Larger-capacity Henry Xtra and George wet and dry machines.
Specification
| Reference | Numatic NVM-2BH |
|---|---|
| Fits | Larger-capacity Henry Xtra and George wet and dry machines |
| Capacity | 15 litres |
| Material | Multi-layer paper with a flo-bag design |
| Bags per box | 10 bags (standard retail pack) |
What to check before you order
The 2BH bag is taller and wider than the standard 1CH bag to match the larger machine body. It will physically fit inside a standard Henry but will not seal correctly and reduces suction, so check your model's capacity first.
How to replace it
- Unplug the vacuum and open the dust compartment door.
- Lift out the full dust bag by its card or plastic collar, keeping it level so it does not spill.
- Check the collar shape against the Numatic NVM-2BH before fitting the new one; a bag that does not sit flush will not seal.
- Slide the new dust bag collar into the machine's bag holder until it clicks or seats fully home.
- Close the compartment door. Most machines will not run, or will run with reduced suction, if the door is not fully latched.
- Run the vacuum briefly on an empty patch of floor to confirm suction feels normal before doing a full clean.
Common mistakes
- Buying by vacuum model number alone instead of checking the bag shape, which leads to a bag that does not seal.
- Reusing a bag past the fill line printed on it, which chokes airflow and can strain the motor.
- Forcing a bag from a different reference into the holder; if it does not seat without pressure, it is the wrong one.
How this reference sits in the Numatic range
Numatic also uses the Numatic NVM-1CH shape, and the two are not interchangeable. Compare before you order:
| Other Numatic reference | Fits | Capacity |
|---|---|---|
| Numatic NVM-1CH | Standard-size Henry (HVR200), Hetty, James and George dry vacuums (the common domestic and light commercial Numatic range) | 9 litres |
How long a pack lasts
A retail pack holds 10 dust bags. At the usual rhythm of one change every four to eight weeks in an average household, that pack covers roughly 10 to 20 months, so most people buy bags once or twice a year rather than monthly.
The 15 litre capacity is the volume the bag holds, not a fitting measurement: two bags of the same capacity can have completely different collars. Use it to judge how often you will be changing the bag, and the collar shape to judge whether it fits. Our guide on how often to change a vacuum bag explains what shortens that interval.
Where this information comes from
The specification above is taken from Numatic official spares documentation and Henry Hoover Shop UK product listings. References are re-checked when a manufacturer renumbers a pack; if you find a discrepancy with your own machine, tell us and the page is corrected.
Detailed fitting check before the bag is put into service
Do the fitting check with the machine unplugged, the drum empty, and the old bag removed. Allow 5 minutes for the check. A torch, a ruler marked in millimetres, and a dry cloth are enough. Do not judge the bag only by its loose paper body, because the critical parts are the collar opening, the position of the collar in the holder, and the free space inside the drum.
- Clean the bag holder first. Dust packed behind the holder can hold the collar 2 mm to 3 mm away from its seat, which is enough to leak fine dust.
- Place the collar into the holder without opening the bag fully. It should sit flat before the paper body is expanded.
- Check the hose inlet from inside the drum. The inlet should pass through the collar opening without pushing the collar sideways.
- Close the lid slowly and feel for resistance. A correct fit gives even pressure from the lid seal, not a hard stop on one side.
- After a 10 second test run, switch off and look inside. Fresh dust marks around the collar mean bypass leakage, even if suction still feels acceptable.
If the collar rocks, creases, or needs force, stop and compare it with the smaller Numatic pattern before continuing. The usual comparison point is the Numatic NVM-1CH bag, because it is close enough in general appearance to be confused, but it uses a different size and seating arrangement.
Equipment, measurements, and tolerances to use
The useful measurements are not the inflated size of the paper bag. Paper folds vary, and an unused bag can look smaller than it is. Measure the machine and the collar contact points instead. A normal steel ruler is accurate enough, but a vernier caliper makes the collar opening easier to check. Write the figures down before ordering if the label on the cleaner is worn.
| Check point | How to measure it | Practical limit to watch |
|---|---|---|
| Collar seating flatness | Lay the fitted collar against the holder and look along the edge with a torch. | A visible gap over 2 mm is enough to justify stopping and checking the reference again. |
| Hose inlet alignment | Look through the inlet from the drum side before the bag is opened out. | The inlet should be central in the collar hole, not touching one side of the collar. |
| Bag clearance inside the drum | Spread the empty bag gently and close the lid without switching on. | The lid should close without compressing a folded corner into the seal. |
| First fill level check | Inspect after the first 15 to 20 minutes of real cleaning. | The bag should expand evenly, not balloon only at the neck. |
| Fine dust use | Check suction and bag surface during the first job. | Plaster dust, ash, or very fine sanding dust can blind the bag surface long before the volume is full. |
Keep one unused bag as a pattern if several people maintain the same cleaner. Mark the storage shelf with the vacuum name rather than relying on memory. This avoids mixing larger Numatic bags with standard domestic bags when both types are kept in the same cupboard. General brand navigation is available from the Numatic bags page.
Frequent faults after fitting, and how to recover
If suction is poor immediately after a new bag is fitted, do not assume the bag material is blocked. First check for an air leak. A leaking collar can reduce pickup while leaving the motor sounding almost normal. Remove the bag, wipe the holder, refit it, and close the lid again. This takes less than 2 minutes and solves many first fit problems.
If dust appears inside the drum outside the bag, discard the bag after correcting the cause. Once dust has passed behind the collar, the sealing face may be dirty and the bag neck may be distorted. Clean the drum with a dry cloth, then check the machine filter before running it again. Running for several hours with bypass dust can load the filter heavily and reduce airflow on the next bag.
If the bag has been overfilled, remove it level and slowly. A heavy 15 litre bag can tear at the neck if lifted by one corner. Support the underside with one hand, keep the collar upright, and avoid shaking it inside the drum. If the cleaner was used until suction dropped sharply, inspect the hose and inlet bend, because compacted debris often remains there after the bag is removed.
If the lid will not latch, do not press it down with body weight. Open it, rotate the bag body so the folded paper sits lower in the drum, and check that no corner is trapped on the rim. A trapped fold can create a false seal at first, then move during use and release dust into the compartment.
Special cases: mixed debris, damp work, and shared machines
For mixed workshop debris, change the bag earlier than the printed fill mark if the cleaner has picked up fine powder. A bag can be only one third full by volume and still have poor airflow if the surface is coated with cement dust, filler dust, or soot. In that situation, the useful guide is suction and motor note, not capacity.
For any machine also used around wet work, fit a dry bag only when the drum, hose, and inlet are dry. Damp paper can soften at the collar and lose its shape. If the cleaner has recently been used for liquid pickup, leave the drum open until dry and wipe the inlet before fitting the bag. Do not store spare bags inside a damp drum.
For schools, offices, and shared sites, attach a simple change card to the cleaner. Record the date, the area cleaned, and the reason for the change. After 3 to 4 changes, the pattern is usually clear. A cleaner used daily in a dusty entrance may need a bag far sooner than a similar cleaner used weekly in a small office. If the symptom is unclear, use the troubleshooting questions on the vacuum bag FAQ before ordering another reference.
Read next
- How to measure your vacuum bag: A step by step way to measure an old vacuum bag and match it to the correct replacement reference.
- What to do if your model is not listed: Steps to take if you cannot find your exact vacuum model in our catalogue, without guessing at a bag reference.
- Where to find your vacuum's bag reference: The three places to check on your vacuum cleaner to find the exact bag reference or model number.