Hoover H30 dust bags
If your machine is one of the models below, the bag you need is the Hoover H30 (Freespace, Telios Extra range).
Hoover Freespace and Telios Extra cylinder vacuum ranges.
Specification
| Reference | Hoover H30 (Freespace, Telios Extra range) |
|---|---|
| Fits | Hoover Freespace and Telios Extra cylinder vacuum ranges |
| Capacity | 3.5 litres (typical for the H30 shape) |
| Material | Multi-layer synthetic fleece with card collar |
| Bags per box | 4 bags plus filters (standard retail pack) |
What to check before you order
The H30 collar is a different width to the H64 collar. If your existing bag does not sit flush against the inlet, you most likely have the wrong reference for your model.
How to replace it
- Unplug the vacuum and open the dust compartment door.
- Lift out the full dust bag by its card or plastic collar, keeping it level so it does not spill.
- Check the collar shape against the Hoover H30 (Freespace, Telios Extra range) before fitting the new one; a bag that does not sit flush will not seal.
- Slide the new dust bag collar into the machine's bag holder until it clicks or seats fully home.
- Close the compartment door. Most machines will not run, or will run with reduced suction, if the door is not fully latched.
- Run the vacuum briefly on an empty patch of floor to confirm suction feels normal before doing a full clean.
Common mistakes
- Buying by vacuum model number alone instead of checking the bag shape, which leads to a bag that does not seal.
- Reusing a bag past the fill line printed on it, which chokes airflow and can strain the motor.
- Forcing a bag from a different reference into the holder; if it does not seat without pressure, it is the wrong one.
How this reference sits in the Hoover range
Hoover also uses the Hoover H64 shape, and the two are not interchangeable. Compare before you order:
| Other Hoover reference | Fits | Capacity |
|---|---|---|
| Hoover H64 (Purepower, TRTE range) | Hoover Purepower and TRTE cylinder vacuum ranges | 3 litres (typical for the H64 shape) |
How long a pack lasts
A retail pack holds 4 dust bags. At the usual rhythm of one change every four to eight weeks in an average household, that pack covers roughly 4 to 8 months, so most people buy bags once or twice a year rather than monthly.
The 3.5 litre capacity is the volume the bag holds, not a fitting measurement: two bags of the same capacity can have completely different collars. Use it to judge how often you will be changing the bag, and the collar shape to judge whether it fits. Our guide on how often to change a vacuum bag explains what shortens that interval.
Where this information comes from
The specification above is taken from dustbag.co.uk Hoover fitment listings, cross-checked against Hoover UK product documentation. References are re-checked when a manufacturer renumbers a pack; if you find a discrepancy with your own machine, tell us and the page is corrected.
Detailed fitting procedure with checks before closing the door
Allow 3 to 5 minutes for a careful bag change, and work over a bin bag, newspaper, or a washable floor area. Fine dust escapes most often during the first 10 seconds after the old collar is moved, so keep the bag opening higher than the bottom of the bag and avoid squeezing the soft body.
Before touching the dust bag, switch the cleaner off at the socket and remove the plug. Let the machine stand for about 60 seconds so the dust in the hose and inlet settles. Open the dust compartment slowly and look for loose debris around the inlet spigot, the rubber seal, and the bag holder rails. Remove this debris with a dry cloth or a soft brush. Do not use water inside the bag compartment, because damp dust can cake on the seal and reduce airflow.
Fit the new bag with the collar flat and square to the holder. Use light pressure only. A correctly seated collar should not bow, twist, or leave a visible gap at the inlet. If the door needs unusual force to close, stop and remove the bag again. Forcing the latch can bend the holder or trap part of the bag body between the door and the housing.
After closing the compartment, run the vacuum for 10 to 15 seconds on a clean hard floor area. Listen for a steady motor note. A high pitched sound, pulsing suction, or dust smell after a bag change usually means the collar is not sealed, the filter is blocked, or the hose contains a plug of debris.
Equipment, working clearances, and figures to use
- Use a dry microfibre cloth, a soft paintbrush about 25 mm wide, and a torch to inspect the bag bay and seal.
- Keep at least 30 cm of clear space around the vacuum so the hose and lid do not pull against the open compartment.
- Allow 10 to 15 seconds for the final suction test, not a full room clean, because a wrongly seated bag should be found before dust is drawn past it.
- Check the pre motor filter every second bag change in homes with normal dust, and at every bag change if the vacuum is used for pet hair, ash trace, plaster dust, or very fine debris.
- Leave a small air space inside the fitted bag body. Do not fold or pack it tightly into the compartment, because the bag needs room to inflate when airflow starts.
| Check point | What to look for | Practical limit |
|---|---|---|
| Collar seating | The collar lies flat against the inlet area. | No visible gap around the inlet before the door is closed. |
| Bag body position | The soft bag is inside the compartment and clear of the door edge. | No fabric or fleece trapped in the latch line. |
| Dust escape check | No puff of dust from the lid or exhaust during start up. | Test for 10 to 15 seconds before cleaning a room. |
| Filter condition | The filter surface is grey but not matted or blocked. | If tapping does not clear loose dust, replace or wash only if the filter type permits it. |
| Suction sound | The motor note stays even after fitting the bag. | Pulsing or whistling needs investigation before further use. |
Frequent fitting faults and how to recover
If dust appears inside the bag compartment after fitting, remove the bag and inspect the collar edge. A small crease at the inlet is enough to bypass the bag. Wipe the compartment clean, refit with the collar square, and repeat the short suction test. Do not continue vacuuming with loose dust in the compartment, because that dust can reach the filter and shorten its working life.
If suction is poor immediately after a new bag is fitted, do not assume the bag is full or faulty. Remove the hose and check it separately. A blockage often sits in the first bend of the hose or at the handle. A broom handle can damage flexible hose lining, so use a blunt plastic rod or gently flex the hose while looking through it toward a light source.
If the door closes but springs open when the motor starts, the bag body may be folded in front of the latch area. Open the lid, lift the bag body upward, and let it fall naturally into the compartment. Then close the lid without pushing the soft bag into a compact shape.
If you have compared the collar and it clearly does not match the holder, do not trim card, cut plastic, or tape the opening. That can let dust bypass the bag and reach the motor side. Compare the Hoover family references before ordering again, especially if the vacuum has been bought second hand. The wider Hoover range is grouped at Hoover vacuum bags, and the other common shape is listed at Hoover H64 bags.
Special cases: fine dust, pets, storage, and older machines
Very fine renovation dust fills the pores of a bag long before the visible volume is used. Plaster dust, soot trace, fireplace ash residue, and flour like powders can reduce suction after one short session. If this happens, change the bag and check the filter even if the bag looks almost empty. Domestic cylinder vacuums are not designed as building dust extractors.
Pet hair changes the fill pattern. Hair can create a loose mat near the inlet, while the rear of the bag still looks empty. If the vacuum loses suction in a pet household, tap the outside of the closed compartment lightly before opening it, then inspect the bag shape. A matted inlet area means the bag should be changed rather than shaken and reused.
For stored bags, keep them flat, dry, and away from heavy objects. A bent collar is more important than a creased soft bag, because the collar controls the seal. If a collar has been crushed, do not try to restore it with tape. Use a bag with an undamaged collar.
On older machines, check the lid latch, inlet seal, and bag holder for wear each time you change the bag. A worn latch can let the door lift by 1 or 2 mm under suction, which is enough to cause dust leakage. If you are unsure whether a symptom points to the bag, the filter, or the cleaner body, use the checks in the vacuum bag FAQ before ordering more bags.
Read next
- Panasonic C-20E dust bags: The exact bag reference for Panasonic MC-CG range of cylinder vacuums.
- Vax legacy cylinder dust bags: The exact bag reference for Older Vax 6000 and 6100 series cylinder vacuums.
- How to measure your vacuum bag: A step by step way to measure an old vacuum bag and match it to the correct replacement reference.