Skip to content
Which Vacuum Bag

Bosch and Siemens Type G dust bags

If your machine is one of the models below, the bag you need is the Bosch/Siemens Type G (BBZ52AFG2U / VZ52AFG2U family).

Bosch GL-30, GL-40 and Ergomaxx cylinder ranges; Siemens VSZ and Q-series cylinder ranges built on the same platform.

Specification

ReferenceBosch/Siemens Type G (BBZ52AFG2U / VZ52AFG2U family)
FitsBosch GL-30, GL-40 and Ergomaxx cylinder ranges; Siemens VSZ and Q-series cylinder ranges built on the same platform
Capacity4 litres
MaterialMulti-layer MEGAfilt SuperTEX synthetic fleece
Bags per box4 bags plus a micro-hygiene filter (standard retail pack)

What to check before you order

Type G covers both brands because Bosch and Siemens share their vacuum cleaner platform under parent company BSH. Older Bosch and Siemens models used different letter-coded types (such as Type D or Type E), so confirm the type letter printed near the dust compartment rather than assuming Type G by default.

How to replace it

  1. Unplug the vacuum and open the dust compartment door.
  2. Lift out the full dust bag by its card or plastic collar, keeping it level so it does not spill.
  3. Check the collar shape against the Bosch/Siemens Type G (BBZ52AFG2U / VZ52AFG2U family) before fitting the new one; a bag that does not sit flush will not seal.
  4. Slide the new dust bag collar into the machine's bag holder until it clicks or seats fully home.
  5. Close the compartment door. Most machines will not run, or will run with reduced suction, if the door is not fully latched.
  6. Run the vacuum briefly on an empty patch of floor to confirm suction feels normal before doing a full clean.

Common mistakes

  • Buying by vacuum model number alone instead of checking the bag shape, which leads to a bag that does not seal.
  • Reusing a bag past the fill line printed on it, which chokes airflow and can strain the motor.
  • Forcing a bag from a different reference into the holder; if it does not seat without pressure, it is the wrong one.

How this reference sits in the Bosch range

Bosch/Siemens Type G (BBZ52AFG2U / VZ52AFG2U family) is the only reference published for Bosch on this site, because it is the only one confirmed by a manufacturer or distributor source. Other Bosch machines sold in the UK are bagless, so there is no bag to match. Our Bosch page lists what is covered.

How long a pack lasts

A retail pack holds 4 dust bags. At the usual rhythm of one change every four to eight weeks in an average household, that pack covers roughly 4 to 8 months, so most people buy bags once or twice a year rather than monthly.

The 4 litre capacity is the volume the bag holds, not a fitting measurement: two bags of the same capacity can have completely different collars. Use it to judge how often you will be changing the bag, and the collar shape to judge whether it fits. Our guide on how often to change a vacuum bag explains what shortens that interval.

Where this information comes from

The specification above is taken from Bosch and Siemens official parts documentation, cross-checked against UK retailer fitment guides. References are re-checked when a manufacturer renumbers a pack; if you find a discrepancy with your own machine, tell us and the page is corrected.

Detailed fitting procedure with checks before closing

Work on a hard floor, not carpet, so that any spilled dust is visible and can be wiped up. Let the cleaner stand for 30 to 60 seconds after switching it off, because fine dust remains airborne inside the bag chamber for a short time.

Open the bag compartment fully and look at the two parts that do the sealing: the bag collar and the inlet stub inside the vacuum. The collar must slide squarely into its rails. The rubber or plastic inlet stub must enter the collar hole without folding the bag material around it. If the bag is twisted, remove it and fit it again rather than pushing the door shut.

Before closing the lid, pull the bag body gently downwards and backwards so it unfolds inside the chamber. Do not stretch it tight. A loose, open bag gives the air path more surface area, while a folded bag can block itself within the first few minutes of use.

After closing the lid, run the cleaner for 20 to 30 seconds with the floor head lifted slightly from the floor. Listen for a sharp whistle at the bag door or a pulsing motor note. Either sound usually means air is bypassing the bag or the bag is not seated flat.

Equipment, measurements and working tolerances

You do not need special tools, but a few basic items make the job more reliable. A ruler helps when comparing an old collar with a new one, especially if the printed type letter is worn or hidden by dust.

  • Use a torch to inspect the rails and the inlet stub inside the dust compartment.
  • Use a ruler marked in millimetres to compare the old and new collars across their widest and tallest points.
  • Use a dry cloth to wipe dust from the rails, latch area and sealing face before fitting the new bag.
  • Use a small bin bag beside the vacuum so the used bag can be transferred without carrying it through the house.

If you still have the old bag, compare the collar outline rather than the soft bag body. A difference of 1 to 2 mm at the rail edges can be enough to stop the bag seating correctly. A collar that rocks in the holder, or needs force to enter the holder, should be treated as the wrong fit.

CheckFigure to useWhat it tells you
Collar edge differenceMore than 1 to 2 mmStop and recheck the bag type before fitting.
Door closing forceNo extra pressure beyond normal latch resistanceExtra force usually means the collar is not seated.
Test run time20 to 30 secondsLong enough to hear leaks or pulsing suction.
Dust settling time before removal30 to 60 secondsReduces loose dust escaping when the door opens.

Frequent faults and how to recover

If the lid will not close, do not press down on it. Open it again and check that the collar is fully in its side rails. Also check that the bag body is not trapped under the hinge side of the lid. A trapped corner can hold the door open by only a few millimetres, but that is enough to break the seal.

If suction is weak straight after fitting a fresh bag, remove the hose and look through it towards a light source. A blocked hose can be mistaken for a bag fault. Check the wand and floor head as separate parts, because a coin, hair ball or clump of paper often stops at a joint rather than inside the vacuum body.

If dust appears inside the bag chamber, stop using the cleaner. Remove the bag, wipe the chamber with a dry cloth, and inspect the collar hole for tearing. Also check the inlet stub for hard dirt on its sealing face. Even a small ridge of compacted dust can lift the collar away from the inlet.

If the bag full indicator stays active with a new bag, test the cleaner with the hose removed. If the indicator drops back, the blockage is in the hose, tube or nozzle. If it does not, inspect the filter area and the air path behind the bag. More general checks are covered on the FAQ page.

Special cases to check before ordering again

Some households fill bags by airflow restriction before the bag looks physically full. Fine renovation dust, fireplace ash, flour, talc and pet dander can clog the bag surface quickly. In that case, replace the bag when suction falls rather than waiting for the bag to expand fully. Do not vacuum damp material, because moisture can set dust into a hard layer and can damage filters.

If the vacuum has been stored for months with a used bag fitted, replace the bag before the next use. Old dust can smell, and insects may damage paper or fleece surfaces while the machine is unused.

If you are checking another Bosch cleaner in the same cupboard, do not assume it uses the same bag because the brand matches. Confirm the bag type on the cleaner or compare it with the Bosch information page at Bosch vacuum bags.

Read next